Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 110
Filtrar
1.
Healthcare (Basel) ; 12(9)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38727461

RESUMEN

To improve arthroplasty care quality, the EndoCert initiative focuses on structural, processual, and surgeon-related quality assurance. The aim of this study was to assess the impact of a surgeon's case load in certified centers on quality of care, distinguished by different types of surgeons. Data from the annual reports of EndoCert certified centers for the years 2017 to 2021 were analyzed. The study revealed reduced numbers of cases, while the number of surgeons remained constant. Since 2020, the decrease in the average case load per surgeons has become more pronounced. There were also differences between senior (sECrs) and EndoCert-registered surgeons (ECrs). Before the 2020 pandemic, over half of surgeons exceeded minimum annual case requirements, while, afterwards, this number declined, especially for the ECrs. Affiliated surgeons, who are also sECrs or ECrs, performed predominantly lower numbers of arthroplasties. However, a higher percentage of affiliated surgeons in a center correlated with faster surgeries and lower mortality rates. High numbers of arthroplasties per center or surgeon were not necessarily associated with better quality indicators, especially in the knee. While the comprehensive quality standards may offset volume effects, EndoCert should reconsider minimum volume regulations based on surgeon, but also on each joint.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38735362

RESUMEN

OBJECTIVE: Ectopic articular calcification is a common phenomenon of osteoarthritic joints, and closely related with disease progression. Identification of the involved calcium crystal types represents an important topic in research and clinical practice. Difficulties in accurate detection and crystal type identification have led to inconsistent data on the prevalence and spatial distribution of BCP and CPP deposition. METHOD: Combining multiple imaging methods including conventional radiography, histology and Raman spectroscopy, this study provides a comprehensive analysis of BCP and CPP based calcification, its frequency and distribution in cartilage and synovial membrane samples of 92 OA patients undergoing knee replacement surgery. RESULTS: Conventional radiography showed calcifications in 35% of patients. Von Kossa staining detected calcified deposits in 88% and 57% of cartilage and synovial samples, respectively. BCP crystals presented as brittle deposits on top of the cartilage surface or embedded in synovial tissue. CPP deposits appeared as larger granular needle-shaped clusters or dense circular pockets below the cartilage surface or within synovial tissue. Spectroscopic analysis detected BCP crystals in 75% of cartilage and 43% of synovial samples. CPP deposition was only detected in 18% of cartilage and 15% of synovial samples, often coinciding with BCP deposits. CONCLUSION: BCP is the predominant crystal type in calcified cartilage and synovium while CPP deposition is rare, often coinciding with BCP. Distinct and qualitative information on BCP and CPP deposits in joint tissues give rise to the speculation that different disease entities are involved that might need different treatment strategies.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38514008

RESUMEN

BACKGROUND: The purpose of this study was to evaluate the influence of humeral position of Affinis short implant in stemless anatomic total shoulder arthroplasties (STSA) on clinical and radiological results and mid- to long-term survival in the treatment of primary osteoarthritis (OA) of the shoulder. METHODS: 80 patients treated with a stemless shoulder arthroplasty for OA of the shoulder were evaluated with a mean follow-up (FU) of 92 ± 14 months (range 69 to 116 months) by Constant (CS)-Score, Disability of Shoulder, Arm and Hand (DASH)-Score and active range of motion (ROM). Radiographic assessment for bone adaptations and humeral implant position was performed by plain X-rays. Determination of pre- and postoperative center of rotation (COR) was used to assess the restoration of the geometry of the humeral head. The appraisal of proper humeral component positioning was correlated with the functional outcomes. A Kaplan-Meier analysis was calculated, investigating the influence of humeral implant position compared to survival time. Complications were noted. RESULTS: The ROM (p < 0.001), CS-Score (p < 0.001) and DASH-Score (p < 0.001) showed significant improvements after surgery for the entire series. The COR restoration was anatomical in 75 % (n = 60) of all implants and in 25 % (n = 20) non-anatomical (pre- and postoperative COR deviation of 2.7 ± 1.8 mm vs. 5.1 ± 3.2 mm, p = 0.0380). The humeral component position did not affect the functional outcome whereas the ten-year unadjusted cumulative survival rate for the anatomic group was significant higher in comparison with the non-anatomical group (96.7 % vs. 75 %, p = 0.002). The radiological evaluation revealed minor periprosthetic bone adaptions in various forms without clinical significance or further intervention. No revision was necessary due to a failed fixation of the stemless humeral component. CONCLUSIONS: Regarding primary OA of the shoulder, STSA derives excellent long-term survival and clinical outcome. These types of implants are able to restore the geometry of the humeral head. Non-anatomical reconstruction may influence the survival over a long-term period on different pathways. Further studies are necessary to elucidate the effect of humeral component position in STSA on functionality, pain and implant survival rate.

4.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 821-828, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38415965

RESUMEN

PURPOSE: Minced cartilage implantation (MCI) is an evolving technique for the treatment of osteochondral lesions. It was hypothesised that mincing of cartilage may affect chondrocyte viability and phenotype and that embedding in collagen 1 gel results in an improved outcome. The objective of this study was to evaluate the impact of cartilage mincing and whether collagen 1 gel mediates beneficial effects on the chondrocyte phenotype and viability. METHODS: Human cartilage samples from 11 patients undergoing total knee arthroplasty were collected and minced according to the MCI protocol. Minced cartilage was cultured for 1 week with and without embedding in collagen 1 gel and was compared with unminced cartilage flakes as control. Quantitative reverse transcription-PCR and immunohistochemical staining for the chondrocyte marker genes SOX9, COL2, ACAN, COL10 and MMP13 were used to examine the chondrocyte phenotype. Cell death was assessed by the terminal deoxynucleotidyl transferase dUTP nick-end labeling assay. RESULTS: Increased chondrocyte cell death of cultured cartilage after mincing was observed. Chondrocytes from minced cartilage exhibited significantly decreased expression and protein levels of homeostatic and hypertrophic chondrocyte markers. Embedding in collagen 1 gel showed no positive effect on viability. However, remarkable is the increased expression of ACAN and the preserved protein level of SOX9 in the collagen 1-embedded minced cartilage. CONCLUSIONS: This study shows that the mincing of cartilage leads to increased chondrocyte death and decreased expression of chondrocyte phenotypic marker genes after 7 days. The use of collagen 1 gel may improve the stability of the phenotype, which needs to be further elucidated. LEVEL OF EVIDENCE: Level III (therapeutic).


Asunto(s)
Cartílago Articular , Cartílago , Adulto , Humanos , Condrocitos/patología , Fenotipo , Hipertrofia/metabolismo , Hipertrofia/patología , Colágeno/metabolismo , Cartílago Articular/patología
5.
J Mech Behav Biomed Mater ; 150: 106326, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38141361

RESUMEN

Implant modularity within revision total hip arthroplasty (THA) offers multiple implant configurations and allows surgeons a high intraoperative flexibility to restore functionality to the patients joint, even in complex revision cases. However, a rare but devastating complication for patients, clinicians and manufacturers presenting a breakage of the taper junction between the distal stem and the proximal implant part. Aside from implant and patient specific risk factors, corrosion and fretting at the stem junctions have been associated with taper failure. Whether corrosive processes are a precursor of failure or rather an accompaniment of material fatigue is thereby still unclear. Therefore, this study aims to investigate the incidence of taper corrosion in a collection of 17 retrievals from a single type (MRP-Titan, Peter Brehm GmbH) and on the correlation of taper corrosion to implant and patient specific factors. None of the implants was revised for problems related to the taper junction, corrosion or the implant itself. The modular stem junction of all retrievals was visually rated with respect to corrosion, fretting and surface contamination. Additionally, the stability of taper junctions of retrievals where the proximal part with the neck was still assembled to the stem was determined by measuring the loosening moment of the securing screw and the push-out-force for taper dissociation. There was no difference between the mean push-out-force of the retrievals (14 kN ± 1.2 kN) and new reference samples (12.6 kN ± 0.5 kN). Approximately one third of the investigated retrievals showed considerable taper corrosion. The extent of corrosion increased with time in vivo and contamination of the neck piece, while it decreased with the loosening moment of the locking screw. The parameters femoral head offset, neck piece length, lateralized neck pieces, obesity of patients and septic/aseptic revision were not correlated to taper corrosion. Taper corrosion seems to occur regularly in modular taper junctions and is not necessarily connected to taper failure. A correct assembly of the junction and avoiding taper surface contamination during revision surgery is mandatory.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Prótesis de Cadera/efectos adversos , Corrosión , Diseño de Prótesis , Reoperación , Falla de Prótesis
6.
Cartilage ; : 19476035231212608, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38041252

RESUMEN

OBJECTIVE: Loose bodies are free-floating tissues of cartilage and bone that can cause pain, swelling, the inability to straighten the knee, or intermittent locking of the knee. Loose bodies can arise from degenerative joint disease, flake fractures, osteochondritis dissecans, or chondromatosis. We hypothesized that loose bodies can be classified in stages with tissue characteristics similar to endochondral ossification. DESIGN: Loose bodies were harvested from patients undergoing joint replacement. Samples were processed for histology, gene expression analysis, and micro-computed tomography (µCT). Cartilage- and bone-related genes and proteins were selected for immunofluorescence stainings (collagen type I, II, and X, SOX9 [SRY-box transcription factor 9], and MMP13 [matrix metalloproteinase 13]) and gene expression analysis (FN [fibronectin], COL1A1, COL2A1, COL10A1, SOX9, MMP13, and aggrecan [ACAN]). RESULTS: Loose bodies were grouped in 4 stages: fibrous, (mineralized) cartilaginous, cartilage and bone, and bone. Hyaline-like cartilage tissue with Benninghoff arcades was present in stages 2 and 3. A transition from cartilaginous to mineralized tissue and bone trabecula was defined by an increase in COL1A1 and COL10A1 (stage 3 vs. 4: p = 0.047) positive area. Stage 4 showed typical trabecular bone tissue. The relative volume of calcified tissue (mineralized cartilage and bone tissue) decreased with stages (stages 1-2 vs. 3: p = 0.002; stage 1-2 vs. 4: p = 0.012). COL2A1 expression and stained area decreased from stages 1-2 to 4 (p = 0.010 and p = 0.004). ACAN expression decreased from stage 1-2 to stage 3 (p = 0.049) and stage 4 (p = 0.002). CONCLUSION: Loose bodies show tissue characteristics similar to endochondral ossification. They are probably a relevant substrate for regenerative therapeutic interventions in joint disease.

7.
Z Rheumatol ; 82(10): 852-858, 2023 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-37819406

RESUMEN

Total arthroplasty of the ankle joint (TAA) has become an established treatment option for patients with advanced osteoarthritis of the ankle joint. A crucial factor for good long-term clinical results and standing times is careful patient selection, taking the indications, contraindications, and defined prognostic factors into account. Despite modern prosthetic designs, TAA remains a complex surgical procedure that requires precise surgical techniques in a specialized center. Various limitations exist, such as the implantation technique and experience of the surgeon and perioperative complications due to concomitant medications. Current research focuses on the optimization of implant designs, development of personalized surgical techniques, improvement of the long-term performance and minimization of perioperative complications. Future developments, such as the introduction of robot-assisted surgical systems and the integration of biological procedures are also discussed as technological perspectives.


Asunto(s)
Articulación del Tobillo , Osteoartritis , Humanos , Articulación del Tobillo/cirugía , Osteoartritis/cirugía , Artroplastia , Resultado del Tratamiento
8.
Int J Mol Sci ; 24(15)2023 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-37569721

RESUMEN

Osteoarthritis (OA) is a chronic joint disease characterized by articular cartilage calcification, loss of articular cartilage, bone changes, pain, and disability. Cartilage calcification is one hallmark of OA and is predominantly caused by basic calcium crystals formed due to an imbalance of the pyrophosphate pathway. Sortilin is a transmembrane protein that contributes to vascular calcification in atherosclerosis by externalizing alkaline phosphatase (ALP)-containing vesicles. Calcification in atherosclerosis and osteoarthritis has been associated with cellular senescence. The aim of this study was to investigate the potential role of sortilin and senescence in osteoarthritis-dependent cartilage calcification. Osteoarthritic cartilage from human knee joints was collected after joint replacement, and samples were analyzed by immunohistochemistry and quantitative RT-PCR analysis. Human chondrocytes were treated with osteogenic medium for up to 21 days to induce calcification. Western blots for sortilin and ALP, as well as an ALP activity assay, were performed. Human chondrocytes were treated with mitomycin C to induce senescence, and sortilin expression was quantified at the protein and gene levels. Sections of knee joints from a murine model of osteoarthritis were stained for sortilin and p16 and analyzed by immunohistochemistry. Treatment of wild-type chondrocytes using an osteogenic medium similar to human chondrocytes was performed. Osteoarthritic cartilage from mouse and human knee joints showed an increased number of sortilin and p16-positive chondrocytes compared to healthy cartilage. This observation was corroborated by increased gene expression of sortilin and p16 in mild and moderate osteoarthritic cartilage samples. To investigate the mechanism of sortilin regulation, human chondrocytes were treated with osteogenic medium to induce calcification. Sortilin protein levels and expression were increased after 7 days of stimulation, whereas ALP levels and activity were upregulated after 21 days of stimulation. Similar observations were made in a murine osteoarthritis model. Mechanistically, senescent chondrocytes induced by mitomycin C showed an upregulation of sortilin and ALP gene expression compared to non-senescent chondrocytes. Our data indicate that sortilin and ALP are upregulated during cartilage calcification, which is associated with chondrocyte senescence and thus might contribute to the pathogenesis of osteoarthritis. Cellular senescence seems to induce sortilin expression.

9.
Bone ; 175: 116852, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37473933

RESUMEN

In vivo corrosion of modular endoprostheses remains a great concern, as the release of heavy metal ions can impair the implant's service life and the wellbeing of the patient. The detailed corrosion mechanisms that occur in vivo are so far not completely understood. In this context, the effects of implant released cobalt (Co) and chromium (Cr) ions on osteoblast mineralization and gene expression have not been investigated extensively. This comprehensive study aimed at furthering the understanding of in vivo implant corrosion from the clinical signs via prosthesis retrievals and histology of the synovial membranes down to the molecular processes instigated by corrosion products and its effects on bone mineralization. A detailed in vivo failure analysis was performed investigating 22 retrieved hip endoprostheses from different manufacturers and taper material combinations. The aim was to find a correlation of taper damage and especially corrosion to susceptible biomedical alloys and its effect on periprosthetic tissue as well as the clinical implant performance with regard to revision diagnosis and presence of radiolucent lines (RLL). A second part investigated the effects of Co and Cr ions on the in vitro mineralization process of osteoblasts. Cell cultures were exposed to relevant concentrations of CoCl2 and CrCl3 (0 µM, 100 µM, 200 µM) with and without addition of phosphate. Mineralization behavior was analyzed with Alizarin Red assay and Von Kossa staining of calcium depots, alkaline phosphatase activity of osteoblasts and gene expression was analyzed with real time quantitative PCR. The retrieval study provides evidence of in vivo fretting and crevice corrosion on all metallic tapers combined with either ceramic or metal femoral heads. Within the modular taper junctions, selective dissolution of the α phase occurred in wrought TiAl6V4 alloys, and etching of the fine-grained wrought CoCr28Mo6 alloy implants was observed in formed crevices. In addition, significant amounts of wear particles and corrosion products were detected in retrieved synovial membranes. An increased risk for the occurrence of a RLL in the proximal zones was determined for patients with a corroded mixed metal taper. Whereas Co ions have hardly any effects on mineralization, Cr ions cause a significant concentration dependent decrease in mineralization rate of osteoblasts. However, this effect is alleviated by addition of a phosphate source. Our data reveal that Cr ions depleted dissolved phosphates by forming an insoluble complex (CrPO4), which inhibits the phosphate dependent mineralization process. No significant effect of the heavy metal ions on osteoblast activity by means of alkaline phosphate activity as well as on gene expression is determined. This study broadens the understanding of in vivo corrosion of metallic modular implants and its clinically relevant effects on mineralization. Based on these findings, in vivo corrosion of CoCr28Mo6 endoprostheses should be limited to avoid inhibitory effects of Cr3+ on bone mineralization which can contribute to premature implant failure.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Calcinosis , Prótesis de Cadera , Metales Pesados , Humanos , Prótesis de Cadera/efectos adversos , Calcificación Fisiológica , Corrosión , Aleaciones de Cromo , Diseño de Prótesis
10.
Comput Biol Med ; 164: 107272, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37515873

RESUMEN

BACKGROUND: The shift towards minimally invasive surgery is associated with a significant reduction of tactile information available to the surgeon, with compensation strategies ranging from vision-based techniques to the integration of sensing concepts into surgical instruments. Tactile information is vital for palpation tasks such as the differentiation of tissues or the characterisation of surfaces. This work investigates a new sensing approach to derive palpation-related information from vibration signals originating from instrument-tissue-interactions. METHODS: We conducted a feasibility study to differentiate three non-animal and three animal tissue specimens based on palpation of the surface. A sensor configuration was mounted at the proximal end of a standard instrument opposite the tissue-interaction point. Vibro-acoustic signals of 1680 palpation events were acquired, and the time-varying spectrum was computed using Continuous-Wavelet-Transformation. For validation, nine spectral energy-related features were calculated for a subsequent classification using linear Support Vector Machine and k-Nearest-Neighbor. RESULTS: Indicators derived from the vibration signal are highly stable in a set of palpations belonging to the same tissue specimen, regardless of the palpating subject. Differences in the surface texture of the tissue specimens reflect in those indicators and can serve as a basis for differentiation. The classification following a supervised learning approach shows an accuracy of >93.8% for the three-tissue classification tasks and decreases to 78.8% for a combination of all six tissues. CONCLUSIONS: Simple features derived from the vibro-acoustic signals facilitate the differentiation between biological tissues, showing the potential of the presented approach to provide information related to the interacting tissue. The results encourage further investigation of a yet little-exploited source of information in minimally invasive surgery.


Asunto(s)
Acústica , Tacto , Vibración , Palpación , Procedimientos Quirúrgicos Mínimamente Invasivos
11.
EFORT Open Rev ; 8(5): 283-290, 2023 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-37158429

RESUMEN

Digitization in orthopaedics and traumatology is an enormously fast-evolving field with numerous players and stakeholders. It will be of utmost importance that the different groups of technologists, users, patients, and actors in the healthcare systems learn to communicate in a language with a common basis. Understanding the requirements of technologies, the potentials of digital application, their interplay, and the combined aim to improve health of patients, would lead to an extraordinary chance to improve health care. Patients' expectations and surgeons' capacities to use digital technologies must be transparent and accepted by both sides. The management of big data needs tremendous care as well as concepts for the ethics in handling data and technologies have to be established while also considering the impact of withholding or delaying benefits thereof. This review focuses on the available technologies such as Apps, wearables, robotics, artificial intelligence, virtual and augmented reality, smart implants, and telemedicine. It will be necessary to closely follow the future developments and carefully pay attention to ethical aspects and transparency.

12.
Eur J Orthop Surg Traumatol ; 33(8): 3623-3630, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37253875

RESUMEN

BACKGROUND: Shoulder impingement syndrome (SIS) is one of the most common diseases of the shoulder and can be addressed with various therapeutic concepts. Orthobiological agents such as platelet rich plasma with a low side effect rate gain importance in the conservative treatment of SIS. Currently, the knowledge about success rate influencing factors, such as the growth factors (GF) concentration or acromion type, is limited. The aim of this study was to analyze the clinical outcome in the therapy of external SIS using autologous conditioned plasma combined with recombinant human collagen scaffold (ACP/STR) injection in comparison with a corticosteroid-local anesthetic (CSA) injection. Additionally, the influence of potential limiting factors such as GF concentration, age and acromial morphology was proved. MATERIALS AND METHODS: This prospective pseudo-randomized trial recruited 58 patients with external SIS who received an ultrasound-guided subacromial injection either an ACP/STR or a CSA followed by physical therapy. Follow-up (FU) was performed at 6 weeks, 3 and 6 months. The outcome was assessed with Constant-Murley score, disability of arm, shoulder and hand score and simple shoulder test. The concentration of GF was measured using ELISA. RESULTS: During the FU, the improvement of outcome measures was observed with no differences between both groups. Shoulder force was significantly increased in the ACP/STR group (p < 0.01). We found no correlation between the amount of GF and age or gender in the ACP/STR patients. An acromion Bigliani type III predisposes for therapy failure (p < 0.001, OR = 56) in both treatment groups. CONCLUSIONS: Patients with SIS benefit regarding to PROMs after both ACP/STR and CSA injection and physical therapy. Patients who received ACP/STR obtained superior improvement in force. The quantity of GF did not vary depending on the age, so that ACP/STR can be a treatment option for SIS in elderly patients with multimorbidity. The presence of an acromion type III seems to be a predictive factor for limited effectivity of injections in the clinical management of SIS.


Asunto(s)
Síndrome de Abducción Dolorosa del Hombro , Anciano , Humanos , Corticoesteroides , Anestésicos Locales , Inyecciones , Estudios Prospectivos , Síndrome de Abducción Dolorosa del Hombro/tratamiento farmacológico , Resultado del Tratamiento
13.
Orthopadie (Heidelb) ; 52(7): 587-594, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37093254

RESUMEN

The first severe acute respiratory syndrome coronavirus type 2 (SARS-CoV­2) pandemic wave in Germany in spring 2020 challenged the largely unprepared healthcare system. A prevention concept was implemented to protect the vulnerable patient group at our orthopedic department. The patient triage during the pre-admission process included screening for symptoms and obtaining information on travel, occupation, contact and cluster (TOCC) [16].In March 2020, all sporting events were also cancelled or postponed [12]. Mitigation strategies for sport activities were necessary to restart training and competition. For the professional handball team of the Sport Club Magdeburg (SCM), a hygiene concept including strict mitigation measures combined with a polymerase chain reaction (PCR) test regime was implemented.We reviewed 15,739 patient contacts in a 12-month period at orthopedic department during the SARS-CoV­2 pandemic. This epidemiological, retrospective study presents the results of patient triage detecting cases with suspected SARS-CoV­2 infections when entering the clinic. We also considered 2328 inpatient PCR test results and the infection rates among the medical staff. At the same period, professional athletes underwent 1428 PCR tests as a part of the hygiene concept.During the triage process, 333 cases (2.12%) with suspected SARS-CoV­2 infections were detected at the orthopedic outpatient department. Three patients had a positive PCR test result after triage. Another four positive PCR tests were found among the inpatient group and one positive result among the medical staff. In the athletes' cohort, none of the 1428 PCR tests was positive.Patient triage as a part of the preadmission process is an effective tool to protect the maximum-care hospital from a SARS-CoV­2 mass outbreak. A hygiene concept with a defined PCR test regime protects a professional athlete team from SARS-CoV­2 infections during international competition and training.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/epidemiología , Estudios Retrospectivos , Pandemias/prevención & control , Triaje , Hospitales , Higiene , Pacientes Internos
15.
Front Immunol ; 14: 1112188, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36895567

RESUMEN

Background: Culture-negative periprosthetic joint infections (PJI) are often false diagnosed as aseptic implant failure leading to unnecessary revision surgeries due to repeated infections. A marker to increase the security of e PJI diagnosis is therefore of great importance. The aim of this study was to test C9 immunostaining of periprosthetic tissue as a novel tissue-biomarker for a more reliable identification of PJI, as well as potential cross-reactivity. Method: We included 98 patients in this study undergoing septic or aseptic revision surgeries. Standard microbiological diagnosis was performed in all cases for classification of patients. Serum parameters including C-reactive protein (CRP) serum levels and white blood cell (WBC) count were included, and the periprosthetic tissue was immunostained for C9 presence. The amount of C9 tissue staining was evaluated in septic versus aseptic tissue and the amount of C9 staining was correlated with the different pathogens causing the infection. To exclude cross-reactions between C9 immunostaining and other inflammatory joint conditions, we included tissue samples of a separate cohort with rheumatoid arthritis, wear particles and chondrocalcinosis. Results: The microbiological diagnosis detected PJI in 58 patients; the remaining 40 patients were classified as aseptic. Serum CRP values were significantly increased in the PJI cohort. Serum WBC was not different between septic and aseptic cases. We found a significant increase in C9 immunostaining in the PJI periprosthetic tissue. To test the predictive value of C9 as biomarker for PJI we performed a ROC analyses. According to the Youden's criteria C9 is a very good biomarker for PJI detection with a sensitivity of 89% and a specificity of 75% and an AUC of 0.84. We did not observe a correlation of C9 staining with the pathogen causing the PJI. However, we observed a cross reactivity with the inflammatory joint disease like rheumatoid arthritis and different metal wear types. In addition, we did not observe a cross reactivity with chondrocalcinosis. Conclusion: Our study identifies C9 as a potential tissue-biomarker for the identification of PJI using immunohistological staining of tissue biopsies. The use of C9 staining could help to reduce the number of false negative diagnoses of PJI.


Asunto(s)
Artritis Infecciosa , Artritis Reumatoide , Condrocalcinosis , Infecciones Relacionadas con Prótesis , Humanos , Proteína C-Reactiva/análisis , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Condrocalcinosis/complicaciones , Sensibilidad y Especificidad , Biomarcadores , Artritis Infecciosa/diagnóstico , Artritis Reumatoide/complicaciones
16.
Int J Mol Sci ; 24(6)2023 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-36982177

RESUMEN

Aseptic loosening is the main reason for arthroplasty failure. The wear particles generated at the tribological bearings are thought to induce an inflammatory tissue response, leading to bone loss and the subsequent loosening of the implant. Different wear particles have been shown to activate the inflammasome, thereby contributing to an inflammatory milieu in the direct vicinity of the implant. The aim of this study was to investigate whether the NLRP3 inflammasome is activated by different metal particles in vitro and in vivo. Three different cell lines representing periprosthetic cell subsets (MM6, MG63 and Jurkat) were incubated with different amounts of TiAlV or CoNiCrMo particles. The activation of the NLRP3 inflammasome was determined through the detection of the caspase 1 cleavage product p20 in a Western blot. The formation of the inflammasome was also investigated in vivo using immunohistological staining for ASC in primary synovial tissues as well as tissues containing TiAlV and CoCrMo particles and in vitro after the stimulation of the cells. The results show that the CoCrMo particles induced ASC more markedly, as a readout for inflammasome formation in vivo, compared to TiAlV particular wear. The CoNiCrMo particles also induced ASC-speck formation in all the tested cell lines, which was not induced by the TiAlV particles. The Western blot shows that NRLP3 inflammasome activation, measured through caspase 1 cleavage, was increased only by the CoNiCrMo particles in the MG63 cells. We conclude from our data that the activation of the inflammasome is mainly driven by CoNiCrMo particles and less by TiAlV particles, indicating that different inflammatory pathways are activated by the different alloys.


Asunto(s)
Inflamasomas , Proteína con Dominio Pirina 3 de la Familia NLR , Inflamasomas/metabolismo , Proteína con Dominio Pirina 3 de la Familia NLR/metabolismo , Caspasa 1/metabolismo , Línea Celular , Artroplastia , Interleucina-1beta/metabolismo
17.
Sensors (Basel) ; 23(6)2023 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-36991854

RESUMEN

The direct tactile assessment of surface textures during palpation is an essential component of open surgery that is impeded in minimally invasive and robot-assisted surgery. When indirectly palpating with a surgical instrument, the structural vibrations from this interaction contain tactile information that can be extracted and analysed. This study investigates the influence of the parameters contact angle α and velocity v→ on the vibro-acoustic signals from this indirect palpation. A 7-DOF robotic arm, a standard surgical instrument, and a vibration measurement system were used to palpate three different materials with varying α and v→. The signals were processed based on continuous wavelet transformation. They showed material-specific signatures in the time-frequency domain that retained their general characteristic for varying α and v→. Energy-related and statistical features were extracted, and supervised classification was performed, where the testing data comprised only signals acquired with different palpation parameters than for training data. The classifiers support vector machine and k-nearest neighbours provided 99.67% and 96.00% accuracy for the differentiation of the materials. The results indicate the robustness of the features against variations in the palpation parameters. This is a prerequisite for an application in minimally invasive surgery but needs to be confirmed in realistic experiments with biological tissues.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Robótica , Procedimientos Quirúrgicos Robotizados/métodos , Robótica/métodos , Tacto , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Palpación , Acústica
18.
Orthopadie (Heidelb) ; 52(3): 214-221, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36820851

RESUMEN

In the last decades total hip arthroplasty (THA) has become a standard procedure with many benefits but also a few still unsolved complications, which can lead to surgical revision in 19-23% of cases. Thus, aseptic loosening and metal hypersensitivity remain challenges. The phenomenon of wear debris causes chronic inflammation, which produces osteolysis and aseptic loosening. Wear debris promotes osteoclast production and inhibits osteoblasts by secretion of pro-inflammatory cytokines. Micro-abrasions can be induced by abrasive, adhesive and fatigue wear and cause a liberation of metal ions, which lead to another immune response elicited mostly by macrophages. Another reaction in the neocapsule can be a type IV hypersensitivity reaction to various alloys, containing metals such as nickel, cobalt and chromium. Patch testing and the lymphocyte transformation test (LTT) are not the best diagnostic possibilities to exclude a postoperative hypersensitivity reaction, because of the different alignment of the epicutaneous cells compared to the periprosthetic deep tissue. This hypersensitivity reaction is mostly induced by cytokines, which are secreted by macrophages rather than lymphocytes. In cell cultures and in animal studies, multipotent mesenchymal stem cells (MSC) have been shown to play a role in improving initial implant integration, to limit periprosthetic osteolysis and also to reconstitute peri-implant bone stock during implant revision. Thus, MSC might be used in the future to prolong the durability of THA. A better understanding of the interactions between primary chronic inflammation, corrosion, osteolysis and hypersensitivity is mandatory to develop new therapeutic strategies, aiming at the reduction of the incidence of implant failures. In this article the underlying immunological mechanisms to aseptic loosening are presented.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Hipersensibilidad , Osteólisis , Animales , Artroplastia de Reemplazo de Cadera/efectos adversos , Activación de Linfocitos , Osteólisis/etiología , Metales , Citocinas , Inflamación/complicaciones , Hipersensibilidad/etiología
19.
Acta Biomater ; 158: 827-842, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36599400

RESUMEN

This retrieval study included 43 Biolox delta explants (18 CoC, 25 CoP). Implants were examined macroscopically, whereby damage was evaluated using a semi quantitative scoring system. Confocal microscopy was used to examine wear related damage patterns of the articulating surfaces. Scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) was used to analyze wear marks on the implant surface and wear debris in periprosthetic tissue samples. Raman spectroscopy and X-ray diffraction (XRD) were used to quantify monoclinic zirconia fractions. On all components, in vivo wear resulted predominantly in different damage patterns caused by metal transfer. In CoC bearings stripe wear was additionally detected, and some implants underwent severe damage due to component breakage. The wear scores were higher for CoC components, with no differences between the scores for CoC heads and liners. Wear features caused comparable roughening on implants from CoC and CoP bearings. SEM studies demonstrated that most wear marks were caused by metal debris released from implant components. Grain pull-out was observed in stripe wear regions. Monoclinic phase shift was observed in a similar quantity on components from CoP and CoC bearings. The increase of monoclinic zirconia content around metal deposits was minimal and was more pronounced in areas of stripe wear. The results of this study indicate, that ZTA components in general undergo minimal wear in both, CoC and CoP bearings, however, it is more pronounced in the former. Metal deposits, as the most common wear feature, have no significant effect on monoclinic phase transition. STATEMENT OF SIGNIFICANCE: In this paper, we classify all damage patterns macroscopically according to an established scoring system and assess them regarding surface roughness (confocal microscopy) and monoclinic phase content (Raman spectroscopy) in order to derive the severity for patients. We compare hard-hard and hard-soft bearings and relate damage patterns with metal transfer based on SEM/EDS examinations. Furthermore, we work out correlations between patient-specific data, cause of revision and the physical condition of each individual sample Our cohort consists of 43 Biolox delta retrievals, a comparatively large quantity. In addition, we address current topics such as metal transfer and, based on the classification of damage patterns, provide incentives and/or meaningful focal points for further research.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Ensayo de Materiales , Circonio/química , Diseño de Prótesis , Cerámica/química , Propiedades de Superficie , Falla de Prótesis
20.
J Biomed Mater Res B Appl Biomater ; 111(4): 946-957, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36479964

RESUMEN

Alloys made of CoCrMo are well established as implants materials since decades in orthopedic surgery. The good mechanical properties, biocompatibility and especially the corrosion resistance are important rationales for the use of these alloys. Nevertheless, retrieved implants from revision surgery showed the occurrence of abrasion and corrosion. The wear mechanisms and the occurring corrosion processes might be reduced with a functionalization of the surface. The hexagonal phase of the cobalt chromium matrix plays an important role in the surface functionalization. It can be specifically transformed and set during the manufacturing process. One possibility for the induction of the transformation is the use of a deep rolling process in combination with a novel "sub-zero" cooling strategy during machining. The influence of force and temperature during the deep rolling process on the formation of the hexagonal Co-phase is examined in this study. The results from the targeted setting of the hexagonal Co-phase in the subsurface are shown. For this purpose, EBSD studies have been carried out to detect and quantify the proportion of Co-hex phase in the subsurface of the modified alloys. To analyze the mechanical properties, we measured the residual stress and hardness in the near surface layer under conditions close to the application. Furthermore, we performed biological tests to show a potential influence of the modification on the biocompatibility when using the sub-zero cooling approach. We observed no negative effect on the osteoblastic cell line which attached similarly to all tested surfaces. The investigations provide first insights into the potential use of "sub-zero" cooling in modifying orthopedic implant materials, but also the respective limits with regard to the surface functionalization. Deep rolling in combination with an innovative cooling strategy has a great potential to improve the mechanical properties of CoCr28Mo6 wrought alloy, by subsurface hardening and phase transformation.


Asunto(s)
Aleaciones , Prótesis e Implantes , Fenómenos Mecánicos , Dureza , Corrosión , Propiedades de Superficie , Ensayo de Materiales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...